12.12.2012 Views

Vertical Upflow Horizontal Left Air Handlers - Trane

Vertical Upflow Horizontal Left Air Handlers - Trane

Vertical Upflow Horizontal Left Air Handlers - Trane

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Vertical</strong> <strong>Upflow</strong><br />

<strong>Horizontal</strong> <strong>Left</strong><br />

<strong>Air</strong> <strong>Handlers</strong><br />

2TGB018-048A<br />

1½ – 5 Ton<br />

PUB. NO. 22-1778-01


© AMERICAN STANDARD INC. 2006<br />

<strong>Vertical</strong> <strong>Upflow</strong><br />

<strong>Horizontal</strong> <strong>Left</strong> <strong>Air</strong> <strong>Handlers</strong><br />

Features:<br />

• Full line 1 1/2 - 5 tons<br />

Expanded application fit with narrow<br />

cabinet profile<br />

Maximum depth 21" - fits pull-down<br />

staircase<br />

Exclusive maximum width 23.5" - fits<br />

2-ft. wide door all sizes<br />

Convertible upflow to horizontal left<br />

(no tools required)<br />

Attractive enamel finish<br />

R 4.2 - 1" foil faced insulation<br />

Versatile duct flange - allows flush fit<br />

3/4", 1" or 1.5" duct insulation<br />

Tight cabinet - low leakage by design<br />

IAQ (Indoor <strong>Air</strong> Quality) sloped/free<br />

draining pan (no standing water)<br />

Durable, glass-filled Lexan - Never<br />

rust, no leak drain pan<br />

Exclusive easy clean coil and drain pan<br />

Exclusive standard size replaceable<br />

fiberglass filters<br />

Easy to remove filters and blowers for<br />

easy cleaning and replacement<br />

Filter panel stamped with word “filter”<br />

Easy access electrical controls and<br />

hook-up<br />

Built-in time delay<br />

Direct drive motor<br />

Polarized plugs for easy hook-up to<br />

electric heaters<br />

200/230 volt primary and 24 volt<br />

secondary transformer<br />

Electric heaters with breaker option on<br />

all sizes<br />

AccuTron refrigerant control<br />

Expansion valve (bleed TXV)<br />

standard on 5-ton model<br />

Optional extended warranties<br />

2 Pub. No. 22-1778-01


MODEL<br />

RATED VOLTS/PH/HZ.<br />

RATINGS1<br />

INDOOR COIL — Type<br />

Rows — F.P.I.<br />

Face Area (sq. ft.)<br />

Tube Size (in.)<br />

Refrigerant Control<br />

Drain Conn. Size (in.) 2<br />

INDOOR FAN — Type<br />

Diameter-Width (in.)<br />

No. Used<br />

Drive - No. Speeds<br />

CFM vs. in w.g.1<br />

No. Motors — H.P.<br />

Motor Speed R.P.M.<br />

Volts/Ph/Hz<br />

F.L. Amps - L.R. Amps<br />

FILTER<br />

<strong>Vertical</strong> Applications<br />

Filter Furnished?<br />

Lo. Vel. (No.-Size-Thk)<br />

<strong>Horizontal</strong> Applications<br />

Filter Furnished?<br />

Recommended Size 3<br />

REFRIGERANT (R-22)<br />

Ref. Line Connections<br />

Conn. Size — in. Gas<br />

Conn. Size — in Liq.<br />

DIMENSIONS<br />

Crated (in.)<br />

Uncrated<br />

WEIGHT<br />

Shipping (Lbs.) / Net (Lbs.)<br />

MODEL<br />

RATED VOLTS/PH/HZ.<br />

RATINGS1<br />

INDOOR COIL — Type<br />

Rows — F.P.I.<br />

Face Area (sq. ft.)<br />

Tube Size (in.)<br />

Refrigerant Control<br />

Drain Conn. Size (in.) 2<br />

INDOOR FAN — Type<br />

Diameter-Width (in.)<br />

No. Used<br />

Drive - No. Speeds<br />

CFM vs. in w.g.1<br />

No. Motors — H.P.<br />

Motor Speed R.P.M.<br />

Volts/Ph/Hz<br />

F.L. Amps - L.R. Amps<br />

FILTER<br />

<strong>Vertical</strong> Applications<br />

Filter Furnished?<br />

Lo. Vel. (No.-Size-Thk)<br />

<strong>Horizontal</strong> Applications<br />

Filter Furnished?<br />

Recommended Size 3<br />

REFRIGERANT (R-22)<br />

Ref. Line Connections<br />

Conn. Size — in. Gas<br />

Conn. Size — in Liq.<br />

DIMENSIONS<br />

Crated (in.)<br />

Uncrated<br />

WEIGHT<br />

Shipping (Lbs.) / Net (Lbs.)<br />

2TGB3F18A1000A<br />

208-230/1/60<br />

See O.D. Specs<br />

Plate Fin<br />

3 - 14<br />

2.29<br />

3/8 - Copper<br />

TXV-NB4<br />

3/4 NPT<br />

Centrifugal<br />

10 X 7<br />

1<br />

Direct - 3<br />

See FanTable<br />

1 - 1/6<br />

1060<br />

208-230/1/60<br />

1.15 - 1.72<br />

YES<br />

1 - 16 X 20<br />

NO<br />

See NOTE 3<br />

Brazed<br />

5/8<br />

1/4<br />

H x W x D<br />

47.5 X 21 X 24.5<br />

45.7 X 18 X 21<br />

124 / 109<br />

2TGB3F42A1000A<br />

208-230/1/60<br />

See O.D. Specs<br />

Plate Fin<br />

3 - 14<br />

4.58<br />

3/8 - Copper<br />

TXV-NB4<br />

3/4 NPT<br />

Centrifugal<br />

10 X 10<br />

1<br />

Direct - 3<br />

See FanTable<br />

1 - 1/2<br />

1075<br />

208-230/1/60<br />

3.9 - 8.7<br />

YES<br />

1 - 20 X 20<br />

NO<br />

See NOTE 3<br />

Brazed<br />

7/8<br />

3/8<br />

H x W x D<br />

50.25 X 26 X 24.5<br />

48.25 X 23.5 X 21.5<br />

147 / 131<br />

General<br />

Data<br />

Pub. No. 22-1778-01 3<br />

2TGB3F25A1000A<br />

208-230/1/60<br />

See O.D. Specs<br />

Plate Fin<br />

3 - 14<br />

2.29<br />

3/8 - Copper<br />

TXV-NB4<br />

3/4 NPT<br />

Centrifugal<br />

10 X 7<br />

1<br />

Direct - 3<br />

See FanTable<br />

1 - 1/6<br />

1060<br />

208-230/1/60<br />

1.15 - 1.72<br />

YES<br />

1 - 16 X 20<br />

NO<br />

See NOTE 3<br />

Brazed<br />

3/4<br />

5/16<br />

H x W x D<br />

47.5 X 21 X 24.5<br />

45.7 X 18 X 21<br />

125 / 110<br />

2TGB3F48A1000A<br />

208-230/1/60<br />

See O.D. Specs<br />

Plate Fin<br />

3 - 14<br />

6.19<br />

3/8 - Copper<br />

TXV-NB4<br />

3/4 NPT<br />

Centrifugal<br />

10 X 10<br />

1<br />

Direct - 3<br />

See FanTable<br />

1 - 1/2<br />

1075<br />

208-230/1/60<br />

3.5 - 8.3<br />

YES<br />

1 - 22X 20<br />

NO<br />

See NOTE 3<br />

Brazed<br />

7/8<br />

3/8<br />

H x W x D<br />

59.25 X 26 X 24.5<br />

57.25 X 23.5 X 21.5<br />

172 / 153<br />

2TGB3F30A1000A<br />

208-230/1/60<br />

See O.D. Specs<br />

Plate Fin<br />

4 - 14<br />

2.75<br />

3/8 - Copper<br />

TXV-NB4<br />

3/4 NPT<br />

Centrifugal<br />

10 X 8<br />

1<br />

Direct - 3<br />

See FanTable<br />

1 - 1/4<br />

850<br />

208-230/1/60<br />

2.0 - 2.86<br />

YES<br />

1 - 16 X 20<br />

NO<br />

See NOTE 3<br />

Brazed<br />

3/4<br />

5/16<br />

H x W x D<br />

53.7 X 21 X 24.7<br />

52 X 18 X 21<br />

135 / 119<br />

2TGB3F36A1000A<br />

208-230/1/60<br />

See O.D. Specs<br />

Plate Fin<br />

4 - 14<br />

2.75<br />

3/8 - Copper<br />

TXV-NB4<br />

3/4 NPT<br />

Centrifugal<br />

10 X 8<br />

1<br />

Direct - 3<br />

See FanTable<br />

1 - 1/3<br />

1075<br />

208-230/1/60<br />

2.1 - 5.26<br />

YES<br />

1 - 16 X 20<br />

NO<br />

See NOTE 3<br />

Brazed<br />

7/8<br />

3/8<br />

H x W x D<br />

53.7 X 21 X 24.7<br />

52 X 18 X 21<br />

135 / 119<br />

1 These <strong>Air</strong> <strong>Handlers</strong> are A.R.I. certified with various Split<br />

System <strong>Air</strong> Conditioners and Heat Pumps (ARI STANDARD<br />

210/240). Refer to the Split System Outdoor Unit Product<br />

Data Guides for performance data.<br />

2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76)<br />

3 Minimum filter size for horizontal applications will be<br />

based on airflow selection and will be calculated as follows:<br />

Low Velocity Filter: Face area (Sq. Ft.) = CFM / 300<br />

High Velocity Filter: Face area (Sq. Ft.) = CFM / 500<br />

4 Torque spec for TXV = Tighten 1/6 turn past finger tight


Performance<br />

Data<br />

EXTERNAL<br />

<strong>Air</strong>flow Performance<br />

2TGB3F18A1000A: Wet coil, No Heaters<br />

AIRFLOW (CFM)<br />

STATIC<br />

PRESSURE<br />

VERTICAL HORIZONTAL<br />

(in.w.g.)<br />

230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS<br />

HIGH MED LOW HIGH MED LOW HIGH MED LOW HIGH MED LOW<br />

0 895 830 648 805 735 567 878 814 659 791 727 576<br />

0.1 864 799 625 771 711 545 841 781 626 758 695 548<br />

0.2 828 766 598 738 679 514 802 743 591 722 659 514<br />

0.3 790 731 567 703 644 477 760 702 555 683 621 476<br />

0.4 748 691 531 664 604 437 715 656 517 639 580 437<br />

0.5 702 645 487 619 559 395 665 607 473 591 536 393<br />

0.6 649 590 433 565 506 345 608 552 422 536 486 341<br />

0.7 582 525 364 499 443 283 544 490 358 474 428 276<br />

0.8 497 445 276 419 364 198 468 418 277 401 357 191<br />

0.9 385 347 164 322 263 78 378 335 172 316 267 75<br />

NOTES: With filter, no horizontal drip tray<br />

As shipped, with filter<br />

Small apex baffle<br />

Subtract 0.06" W.G. for downflow<br />

Subtract 0.05"" W.G. for horizontal left<br />

<strong>Air</strong>flow Performance<br />

2TGB3F25A1000A: Wet coil, No Heaters<br />

EXTERNAL<br />

AIRFLOW (CFM)<br />

STATIC<br />

PRESSURE<br />

VERTICAL HORIZONTAL<br />

(in.w.g.)<br />

230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS<br />

HIGH MED LOW HIGH MED LOW HIGH MED LOW HIGH MED LOW<br />

0 1035 965 773 926 854 692 1015 955 786 935 878 702<br />

0.1 992 934 730 885 814 648 962 910 759 891 834 675<br />

0.2 944 884 695 845 777 616 916 864 718 849 792 632<br />

0.3 896 834 661 804 741 582 872 819 674 807 750 586<br />

0.4 849 788 621 761 700 537 824 773 628 761 705 544<br />

0.5 800 744 569 713 651 477 768 725 580 710 655 501<br />

0.6 742 690 501 655 591 403 702 670 521 650 596 444<br />

0.7 665 603 410 582 516 319 625 601 438 579 526 351<br />

0.8 555 453 293 489 424 238 538 510 314 493 441 190<br />

0.9 396 197 146 367 313 174 443 387 122 391 338 -<br />

NOTES: With filter, no horizontal drip tray<br />

As shipped, with filter<br />

Small apex baffle<br />

Subtract 0.06" W.G. for downflow<br />

Subtract 0.05"" W.G. for horizontal left<br />

4 Pub. No. 22-1778-01


Performance<br />

Data<br />

EXTERNAL<br />

<strong>Air</strong>flow Performance<br />

2TGB3F30A1000A: Wet coil, No Heaters<br />

AIRFLOW (CFM)<br />

STATIC<br />

PRESSURE<br />

VERTICAL HORIZONTAL<br />

(in.w.g.)<br />

230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS<br />

HIGH MED LOW HIGH MED LOW HIGH MED LOW HIGH MED LOW<br />

0 1114 988 841 976 835 699 1118 1014 858 992 856 721<br />

0.1 1083 960 817 941 818 682 1080 979 836 969 839 702<br />

0.2 1046 935 799 914 801 665 1036 947 815 939 820 686<br />

0.3 1004 908 781 887 781 647 990 913 792 905 798 669<br />

0.4 958 875 757 856 756 625 942 874 764 867 770 648<br />

0.5 908 834 723 818 725 597 893 827 729 824 734 619<br />

0.6 851 782 679 770 684 562 838 770 685 772 688 581<br />

0.7 783 719 624 708 632 519 772 705 630 709 631 532<br />

0.8 699 645 560 633 565 466 685 630 563 629 562 471<br />

0.9 594 560 491 545 483 404 565 548 485 526 479 398<br />

NOTES: With filter, no horizontal drip tray<br />

As shipped, with filter<br />

Small apex baffle<br />

Subtract 0.06" W.G. for downflow<br />

Subtract 0.05"" W.G. for horizontal left<br />

EXTERNAL<br />

<strong>Air</strong>flow Performance<br />

2TGB3F36A1000A: Wet coil, No Heaters<br />

AIRFLOW (CFM)<br />

STATIC<br />

PRESSURE<br />

VERTICAL HORIZONTAL<br />

(in.w.g.)<br />

230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS<br />

HIGH MED LOW HIGH MED LOW HIGH MED LOW HIGH MED LOW<br />

0 1305 1191 1102 1239 1062 957 1262 1187 1112 1211 1080 967<br />

0.1 1259 1154 1076 1200 1039 947 1211 1146 1080 1164 1051 948<br />

0.2 1209 1112 1041 1154 1012 924 1156 1082 1031 1114 1007 930<br />

0.3 1156 1066 1001 1105 980 895 1099 1012 975 1062 955 902<br />

0.4 1101 1018 958 1054 941 863 1044 946 917 1009 901 858<br />

0.5 1043 968 910 1000 896 826 986 888 860 952 845 797<br />

0.6 981 911 857 939 841 781 922 832 800 889 785 722<br />

0.7 911 843 793 866 776 721 843 768 731 813 715 641<br />

0.8 832 757 713 773 697 636 738 676 641 717 627 568<br />

0.9 739 641 610 649 603 511 593 531 517 592 510 520<br />

NOTES: With filter, no horizontal drip tray<br />

As shipped, with filter<br />

Small apex baffle<br />

Subtract 0.06" W.G. for downflow<br />

Subtract 0.05"" W.G. for horizontal left<br />

Pub. No. 22-1778-01 5


Performance<br />

Data<br />

EXTERNAL<br />

<strong>Air</strong>flow Performance<br />

2TGB3F42A1000A: Wet coil, No Heaters<br />

AIRFLOW (CFM)<br />

STATIC<br />

PRESSURE<br />

VERTICAL HORIZONTAL<br />

(in.w.g.)<br />

230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS<br />

HIGH M-HI LOW HIGH M-HI LOW HIGH M-HI LOW HIGH M-HI LOW<br />

0 1925 1823 1432 1833 1691 1212 1870 1788 1424 1786 1674 1662<br />

0.1 1850 1753 1399 1758 1636 1192 1791 1724 1397 1728 1612 1621<br />

0.2 1765 1676 1363 1686 1563 1168 1717 1648 1358 1657 1545 1558<br />

0.3 1673 1597 1317 1611 1489 1136 1641 1569 1309 1580 1476 1491<br />

0.4 1579 1518 1255 1530 1421 1091 1559 1490 1251 1500 1404 1422<br />

0.5 1484 1440 1175 1439 1358 1031 1466 1411 1184 1416 1328 1350<br />

0.6 1388 1358 1078 1340 1286 956 1363 1326 1105 1326 1244 1262<br />

0.7 1292 1266 966 1233 1182 868 1249 1225 1014 1223 1146 1135<br />

0.8 1192 1154 846 1123 1013 769 1127 1090 906 1096 1027 940<br />

0.9 1084 1008 726 1015 734 663 1003 900 778 933 878 636<br />

NOTES: With filter, no horizontal drip tray<br />

As shipped, with filter<br />

Small apex baffle<br />

Subtract 0.06" W.G. for downflow<br />

Subtract 0.05"" W.G. for horizontal left<br />

EXTERNAL<br />

<strong>Air</strong>flow Performance<br />

2TGB3F48A1000A: Wet coil, No Heaters<br />

AIRFLOW (CFM)<br />

STATIC<br />

PRESSURE<br />

VERTICAL HORIZONTAL<br />

(in.w.g.)<br />

230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS<br />

HIGH M-HI LOW HIGH M-HI LOW HIGH M-HI LOW HIGH M-LO LOW<br />

0 1917 1664 1309 1836 1473 1101 1787 1645 1391 1751 1510 1134<br />

0.1 1830 1615 1308 1767 1447 1108 1715 1579 1366 1678 1465 1157<br />

0.2 1751 1561 1287 1698 1413 1102 1637 1519 1329 1606 1418 1138<br />

0.3 1675 1501 1256 1627 1372 1086 1555 1454 1282 1532 1362 1102<br />

0.4 1596 1437 1218 1551 1322 1059 1472 1376 1223 1451 1295 1062<br />

0.5 1511 1366 1173 1470 1263 1022 1387 1284 1153 1363 1215 1024<br />

0.6 1420 1289 1118 1382 1192 972 1298 1181 1072 1266 1125 983<br />

0.7 1323 1202 1045 1288 1106 905 1201 1075 981 1163 1027 926<br />

0.8 1223 1104 942 1188 1000 817 1091 980 881 1055 929 830<br />

0.9 1126 992 794 1086 869 702 962 911 775 947 840 663<br />

NOTES: With filter, no horizontal drip tray<br />

As shipped, with filter<br />

Small apex baffle<br />

Subtract 0.06" W.G. for downflow<br />

Subtract 0.05"" W.G. for horizontal left<br />

6 Pub. No. 22-1778-01


Performance<br />

Data<br />

Pub. No. 22-1778-01 7<br />

MODULAR AIR HANDLER HEATER MODEL NUMBER BAYHTR<br />

MODEL<br />

NUMBER<br />

APPLICATION<br />

1405<br />

4.80kw<br />

1408<br />

7.68kw<br />

1410<br />

3410<br />

9.60kw<br />

1415<br />

3415<br />

15.36kw<br />

1419<br />

19.20kw<br />

NUMBER OF HEATER RACKS 1 2 2 3 4<br />

2TGB3F18A<br />

2TGB3F25A<br />

2TGB3F30A<br />

2TGB3F36A<br />

2TGB3F42A<br />

2TGB3F48A<br />

A/C or Elec. Furnace L L L N/A N/A<br />

Heat Pump L M H N/A N/A<br />

A/C or Elec. Furnace L L L L N/A<br />

Heat Pump L M M H N/A<br />

A/C or Elec. Furnace L L L L N/A<br />

Heat Pump L L L M N/A<br />

A/C or Elec. Furnace L L L L N/A<br />

Heat Pump L L L M N/A<br />

A/C or Elec. Furnace L L L L N/A<br />

Heat Pump L L L H N/A<br />

A/C or Elec. Furnace L L L L L<br />

Heat Pump L L L H H<br />

(L)Low, (M)Medium, (H)High Indicate minimum heating speed setting for blower/motor<br />

operation. N/A - not applicable


AIRFLOW<br />

CFM<br />

NUMBER OF RACKS<br />

Performance<br />

Data<br />

PRESSURE DROP FOR ELECTRIC HEATERS<br />

IN AIR HANDLER MODELS<br />

1 2 3 4<br />

AIR PRESSURE DROP<br />

INCHES W.G.<br />

600 0.01 0.02 0.02<br />

700 0.01 0.02 0.02<br />

800 0.02 0.03 0.03 0.04<br />

900 0.03 0.03 0.04 0.05<br />

1000 0.04 0.04 0.05 0.06<br />

1100 0.04 0.05 0.06 0.07<br />

1200 0.05 0.06 0.07 0.08<br />

1300 0.06 0.07 0.08 0.09<br />

1400 0.07 0.08 0.10 0.11<br />

1500 0.08 0.09 0.11 0.13<br />

1600 0.09 0.10 0.12 0.15<br />

1700 0.10 0.11 0.14 0.17<br />

1800 0.11 0.13 0.16 0.19<br />

1900 0.13 0.15 0.18 0.21<br />

2000 0.14 0.17 0.23 0.23<br />

HEATER RACKS<br />

HEATER<br />

MODEL NO.<br />

NO. OF<br />

RACKS<br />

BAYHTR1405 1<br />

BAYHTR1408 2<br />

BAYHTR1/3410 2<br />

BAYHTR1/3415 3<br />

BAYHTR1419 4<br />

8 Pub. No. 22-1778-01


Performance<br />

Data<br />

2TGB3F18A WIRING DATA<br />

Indoor Blower Motor Powered from Heater Circuit 1<br />

Number<br />

240 VOLT 208 VOLT<br />

Heater<br />

Model No.<br />

of<br />

Circuits/<br />

Phase<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

BAYHTR1405+++ 1/1 4.80 16400 20 26 30 3.60 12300 17.3 23 25<br />

BAYHTR1408+++ 1/1 7.68 26200 32 41 45 5.77 19700 27.7 36 40<br />

BAYHTR1410+++ 1/1 9.60 32500 40 51 60 7.21 24600 34.7 45 45<br />

BAYHTR3410000 1/3 9.60 32800 34.6 43 50 7.21 24600 30 37 40<br />

* Circuit 1/Circuit 2 (Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amp<br />

+++ = 000, PDC, BRK 000 = pigtails, PDC= contains pull disconnect, BRK=contains Circuit disconnects<br />

IMPORTANT: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical<br />

Codes.<br />

2TGB3F25A WIRING DATA<br />

Indoor Blower Motor Powered from Heater Circuit 1<br />

Number<br />

240 VOLT 208 VOLT<br />

Heater<br />

Model No.<br />

of<br />

Circuits/<br />

Phase<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

BAYHTR1405+++ 1/1 4.80 16400 20 26 30 3.60 12300 17.3 23 25<br />

BAYHTR1408+++ 1/1 7.68 26200 32 41 45 5.77 19700 27.7 36 40<br />

BAYHTR1410+++<br />

BAYHTR3410 000<br />

BAYHTR1415 BRK<br />

BAYHTR3415 000<br />

1/1<br />

1/3<br />

2/1<br />

1/3<br />

9.60<br />

9.60<br />

15.36<br />

15.36<br />

32800<br />

32800<br />

52400<br />

52400<br />

40<br />

34.6<br />

40/24<br />

39.1<br />

Pub. No. 22-1778-01 9<br />

51<br />

43<br />

51*/30<br />

49<br />

60<br />

45<br />

60*/30<br />

50<br />

7.21<br />

7.21<br />

11.52<br />

11.52<br />

24600<br />

24600<br />

39300<br />

39300<br />

34.6<br />

30<br />

34.6/20.8<br />

34<br />

45<br />

37<br />

45*/26<br />

43<br />

* Circuit 1/Circuit 2 (Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amp<br />

+++ = 000, PDC, BRK 000 = pigtails, PDC= contains pull disconnect, BRK=contains Circuit disconnects<br />

IMPORTANT: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical<br />

Codes.<br />

2TGB3F30A WIRING DATA<br />

Indoor Blower Motor Powered from Heater Circuit 1<br />

Number<br />

240 VOLT 208 VOLT<br />

Heater<br />

Model No.<br />

of<br />

Circuits/<br />

Phase<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

BAYHTR1405+++ 1/1 4.80 16400 20 28 30 3.60 12300 17.3 24 25<br />

BAYHTR1408+++ 1/1 7.68 26200 32 43 45 5.77 19700 27.7 37 40<br />

BAYHTR1410+++<br />

BAYHTR3410 000<br />

BAYHTR1415 BRK<br />

BAYHTR3415 000<br />

1/1<br />

1/3<br />

2/1<br />

1/3<br />

9.60<br />

9.60<br />

15.36<br />

15.36<br />

32800<br />

32800<br />

52400<br />

52400<br />

40<br />

34.6<br />

40/24<br />

39.9<br />

53<br />

43<br />

53*/30<br />

50<br />

60<br />

45<br />

60*/30<br />

50<br />

7.20<br />

7.20<br />

11.53<br />

11.53<br />

24600<br />

24600<br />

39300<br />

39300<br />

34.6<br />

30<br />

34.6/20.8<br />

34.8<br />

46<br />

37<br />

46*/26<br />

43<br />

* Circuit 1/Circuit 2 (Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amp<br />

+++ = 000, PDC, BRK 000 = pigtails, PDC= contains pull disconnect, BRK=contains Circuit disconnects<br />

IMPORTANT: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical<br />

Codes.<br />

45<br />

40<br />

45*/30<br />

45<br />

50<br />

40<br />

50*/30<br />

45


Performance<br />

Data<br />

2TGB3F36A WIRING DATA<br />

Indoor Blower Motor Powered from Heater Circuit 1<br />

Number<br />

240 VOLT 208 VOLT<br />

Heater<br />

Model No.<br />

of<br />

Circuits/<br />

Phase<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

BAYHTR1405+++ 1/1 4.80 16400 20 28 30 3.60 12300 17.3 24 25<br />

BAYHTR1408+++ 1/1 7.68 26200 32 43 45 5.77 19700 27.7 37 40<br />

BAYHTR1410+++<br />

BAYHTR3410 000<br />

BAYHTR1415 BRK<br />

BAYHTR3415 000<br />

1/1<br />

1/3<br />

2/1<br />

1/3<br />

9.60<br />

9.60<br />

15.36<br />

15.36<br />

32800<br />

32800<br />

52400<br />

52400<br />

40<br />

34.6<br />

40/24<br />

39.9<br />

53<br />

43<br />

53*/30<br />

50<br />

60<br />

45<br />

60*/30<br />

50<br />

7.20<br />

7.20<br />

11.53<br />

11.53<br />

24600<br />

24600<br />

39300<br />

39300<br />

34.6<br />

30<br />

34.6/20.8<br />

34.8<br />

10 Pub. No. 22-1778-01<br />

46<br />

37<br />

46*/26<br />

44<br />

* Circuit 1/Circuit 2 (Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amp<br />

+++ = 000, PDC, BRK 000 = pigtails, PDC= contains pull disconnect, BRK=contains Circuit disconnects<br />

IMPORTANT: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical<br />

Codes.<br />

2TGB3F42A1000A WIRING DATA<br />

Indoor Blower Motor Powered from Heater Circuit 1<br />

Number<br />

240 VOLT 208 VOLT<br />

Heater<br />

Model No.<br />

of<br />

Circuits/<br />

Phase<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

BAYHTR1405+++ 1/1 4.80 16400 20 30 30 3.60 12300 17.3 27 30<br />

BAYHTR1408+++ 1/1 7.68 26200 32 45 45 5.76 19700 27.7 39 40<br />

BAYHTR1410+++<br />

BAYHTR3410 000<br />

BAYHTR1415 BRK<br />

BAYHTR3415 000<br />

1/1<br />

1/3<br />

2/1<br />

1/3<br />

9.60<br />

9.60<br />

15.36<br />

15.36<br />

32800<br />

32800<br />

52400<br />

52400<br />

40<br />

34.6<br />

40/24<br />

41.5<br />

55<br />

43<br />

55*/30<br />

52<br />

60<br />

45<br />

60*/30<br />

60<br />

7.20<br />

7.20<br />

11.53<br />

11.53<br />

24600<br />

24600<br />

39300<br />

39300<br />

34.6<br />

30<br />

34.6/20.8<br />

36.4<br />

* Circuit 1/Circuit 2 (Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amp<br />

+++ = 000, PDC, BRK 000 = pigtails, PDC= contains pull disconnect, BRK=contains Circuit disconnects<br />

IMPORTANT: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical Codes.<br />

2TGB3F48A1000A WIRING DATA<br />

Indoor Blower Motor Powered from Heater Circuit 1<br />

Number<br />

240 VOLT 208 VOLT<br />

Heater<br />

Model No.<br />

of<br />

Circuits/<br />

Phase<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

Capacity<br />

KW BTUH<br />

Heater<br />

Amps per<br />

Circuit<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overload<br />

Protection<br />

BAYHTR1405+++ 1/1 4.80 16400 20 29 30 3.60 12300 17.3 26 30<br />

48<br />

37<br />

48*/26<br />

45<br />

BAYHTR1408+++ 1/1 7.68 26200 32 44 45 5.77 19700 27.7 39 40<br />

BAYHTR1410+++<br />

BAYHTR3410 000<br />

BAYHTR1415 BRK<br />

BAYHTR3415 000<br />

1/1<br />

1/3<br />

2/1<br />

1/3<br />

9.60<br />

9.60<br />

15.36<br />

15.36<br />

32800<br />

32800<br />

52400<br />

52400<br />

40<br />

34.6<br />

40/24<br />

41.1<br />

54<br />

43<br />

54*/30<br />

51<br />

60<br />

45<br />

60*/30<br />

60<br />

7.20<br />

7.20<br />

11.53<br />

11.53<br />

24600<br />

24600<br />

39300<br />

39300<br />

34.6<br />

30<br />

34.6/20.8<br />

36<br />

BAYHTR1419 BRK 2/1 19.20 65500 32/48 44*/60 45*/60 14.42 49200 27.7/41.6 39*/52 40*/60<br />

* Circuit 1/Circuit 2 (Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amp<br />

+++ = 000, PDC, BRK 000 = pigtails, PDC= contains pull disconnect, BRK=contains Circuit disconnects<br />

IMPORTANT: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical Codes.<br />

48<br />

37<br />

48*/26<br />

45<br />

50<br />

40<br />

50*/30<br />

45<br />

50<br />

40<br />

50*/30<br />

45<br />

50<br />

40<br />

50*/30<br />

45


Field<br />

Wiring<br />

WIRING DIAGRAM FOR 2TGB3F18,25,30,36,42,48A1000A<br />

Pub. No. 22-1778-01 11


Field<br />

Wiring<br />

TWE-G AIR HANDLERS WITH SINGLE SPEED COOLING UNIT, 1 STAGE HEAT<br />

FIELD WIRING DIAGRAMS FOR AIR HANDLERS WITH HEAT PUMP<br />

From Dwg. 21B810091 Rev. 0<br />

From Dwg. 21B810093 Rev. 0<br />

12 Pub. No. 22-1778-01


NOTE 3<br />

Electrical<br />

Data<br />

Unit Wiring Diagram<br />

NOTE 3<br />

Pub. No. 22-1778-01 13<br />

3 . FOR REPLACEMENT FUSE USE ONLY BUSSMANN CAT. NO. GMQ-3 , 2/10, 3.2 A, 300 V RATING.<br />

FUSE AND WH/3 WIRE NOT ON ALL MODELS.<br />

From Dwg. 21C810077 P02


TOP VIEW<br />

SIDE VIEW<br />

RETURN<br />

OPENING<br />

BOTTOM VIEW<br />

MODEL NO. A B C D E<br />

Outline<br />

Drawing<br />

Outline Drawing for 2TGB018-036A<br />

AIRFLOW<br />

VERTICAL UPFLOW<br />

MINIMUM UNIT CLEARANCE TABLE<br />

TO<br />

COMBUSTIBLE<br />

MATERIAL<br />

(REQUIRED)<br />

DISCHARGE<br />

OPENING<br />

AIRFLOW<br />

SERVICE<br />

CLEARANCE<br />

(RECOMMENDED)<br />

SIDES 0" 2"*<br />

FRONT 0" 21"<br />

BACK 0" 0"<br />

INLET DUCT 0" 1"<br />

OUTLET<br />

DUCT<br />

1"*<br />

*1" FOR THE FIRST 3 FT. OF OUTLET DUCT WHEN ELECTRIC<br />

HEATERS ARE INSTALLED. EXCEPT MODELS BAYHTR1405,1408,<br />

AND 1410 ARE APPROVED FOR 0" PLENUM AND DUCT CLEARANCE<br />

IN THE UPFLOW CONFIGURATION ONLY.<br />

Flow<br />

Control<br />

Gas Line<br />

BRAZE<br />

Liq. Line<br />

BRAZE<br />

2TGB3F018A 45.70 18.00 16.00 3.13 5.25 TXV-NB 5/8 1/4<br />

2TGB3F25A 45.70 18.00 16.00 3.13 5.25 FCCV 3/4 5/16<br />

2TGB3F30A 52.00 18.00 16.00 3.13 5.25 FCCV 3/4 5/16<br />

2TGB3F36A 52.00 18.00 16.00 3.13 5.25 FCCV 7/8 3/8<br />

HORIZONTIAL LEFT<br />

DISCHARGE<br />

OPENING<br />

FIG. 1 FIG. 2<br />

FIG. 1 FIG. 2<br />

MODEL NO. F G F G<br />

2TGB3F018A 16 12.12 15 11.12<br />

2TGB3F25A 16 12.12 15 11.12<br />

2TGB3F30A 16 12.12 15 11.12<br />

2TGB3F36A 16 12.12 15 11.12<br />

2TGB3F42A 21.50 12.12 20.50 11.12<br />

2TGB3F48A 21.50 12.12 20.50 11.12<br />

14 Pub. No. 22-1778-01


TOP VIEW<br />

SIDE VIEW<br />

RETURN<br />

OPENING<br />

BOTTOM VIEW<br />

MODEL NO. A B C D E H<br />

Outline<br />

Drawing<br />

Outline Drawing for 2TGB042-048A<br />

AIRFLOW<br />

VERTICAL UPFLOW<br />

MINIMUM UNIT CLEARANCE TABLE<br />

TO<br />

COMBUSTIBLE<br />

MATERIAL<br />

(REQUIRED)<br />

Pub. No. 22-1778-01 15<br />

SERVICE<br />

CLEARANCE<br />

(RECOMMENDED)<br />

SIDES 0" 2"*<br />

FRONT 0" 21"<br />

BACK 0" 0"<br />

INLET DUCT 0" 1"<br />

OUTLET<br />

DUCT<br />

1"*<br />

*1" FOR THE FIRST 3 FT. OF OUTLET DUCT WHEN ELECTRIC<br />

HEATERS ARE INSTALLED. EXCEPT MODELS BAYHTR1405,1408,<br />

AND 1410 ARE APPROVED FOR 0" PLENUM AND DUCT CLEARANCE<br />

IN THE UPFLOW CONFIGURATION ONLY.<br />

Flow<br />

Control<br />

Gas Line<br />

BRAZE<br />

Liq. Line<br />

BRAZE<br />

2TGB3F42A 48.25 23.50 21.50 4.61 6.73 18.75 FCCV 7/8 3/8<br />

2TGB3F48A 57.25 23.50 21.50 4.61 6.73 22.50 TXV 7/8 3/8<br />

DISCHARGE<br />

OPENING<br />

DISCHARGE<br />

OPENING<br />

FIG. 1 FIG. 2<br />

AIRFLOW<br />

HORIZONTAL LEFT<br />

FIG. 1 FIG. 2<br />

MODEL NO. F G F G<br />

2TGB3F42A 21.50 12.12 20.50 11.12<br />

2TGB3F48A 21.50 12.12 20.50 11.12


<strong>Trane</strong> Co.<br />

a business of American Standard, Inc.<br />

6200 Troup Highway<br />

Tyler, TX 75707<br />

www.trane.com<br />

For more information contact<br />

your local dealer (distributor)<br />

Mechanical<br />

Specification Options<br />

Features and General Information<br />

These blower coil units are completely<br />

factory assembled including coil, condensate<br />

drain pan, fan, motor, filters and<br />

controls in an insulated casing that can<br />

be applied in horizontal left or vertical<br />

upflow configuration. This model has<br />

4.2 “R” value insulation and additional<br />

sealing systems.<br />

The unit ships in the left-hand horizontal<br />

configuration and converts to vertical<br />

upflow just by standing the unit on end.<br />

No tools required.<br />

Casing<br />

These models have a rugged galvanized<br />

sheet metal and steel frame construction.<br />

The casing is painted with an enamel<br />

finish. The casing is insulated and<br />

provides knockouts for electrical power<br />

and control wiring.<br />

Refrigerant Circuits<br />

The TGB units have a single refrigerant<br />

circuit. The refrigerant circuit is controlled<br />

by a factory installed flow control check<br />

valve (FCCV).<br />

Coil<br />

Aluminum fin surface is mechanically<br />

bonded to 3/8 inch OD copper tubing.<br />

Coils are factory pressure and leak<br />

tested.<br />

Fan<br />

The blower housing is forward curved,<br />

dynamically balanced with a speed direct<br />

drive fan motor. The fan motor is permanently<br />

lubricated.<br />

Controls<br />

Low voltage fan contactor, and plug-in<br />

module for accessory electric heat<br />

control is included. TGB models also<br />

have a check valve.<br />

Filters<br />

The TGB018A through TGB048A have<br />

standard size filters.<br />

Electric Heaters<br />

Heaters for the TGB air handlers are<br />

available in a wide range of capacities<br />

and voltages with various staging options,<br />

and plug-in control wiring. Heaters<br />

fit inside the internal compartment.<br />

<strong>Trane</strong> has a policy of continuous product and product data improvement, it reserves the right to change design<br />

and specifications without notice.<br />

P.I.